Recovery: Building #ia0112zz, Neal Smith Federal Building Arra Project (project #IIA00013), 210 Walnut Street, DES Moines, IA. Contract Award - Work to BE Delivered Under This Task Order Includes, BUT IS NOT Limited to the Following: Change OUT Existing Electrical and Mechanical Systems to Upgrade Performance of Electrical and Hvac Systems. AS Options, the Following Items Will BE Included in the Scope of Work: a. Option NO. 1 - Construction Phase Services: Option #1: A) Arra Required Projects-Provide and Install Advanced Metering on GAS and Water Building Service Entrances; and Upgrades to the Existing Energy Management Control System (emcs); B) Energy Conservation Measures-Provide and Install Energy Saving Lamps; Office Lighting and Switching Revisions; Daylighting Enhancements; Public Area Time of DAY Controls; Cooling Tower Sewer Abatement; Boiler Automatic Blowdown; Time of DAY Controls for Existing AIR Handling Units and Exhaust Fans; Reset Dual Duct Mixing BOX Static Pressure Sensors; Chiller Control Optimization; Replace Existing AIR Handling Units (ONE for ONE). B. Option #2: Remove Building's Existing Perimeter Induction Units. Provide and Install a NEW Perimeter Radiant Heat System, Including a NEW Ventilation AIR System. C. Option #3: Remove Building's Existing Electrical Power Transformers. Provide and Install NEW Higher Efficiency Transformers. D. Option #4: Provide and Install NEW Motorized and Controlled Window Blind System and NEW Highly Reflective Ceiling System. E. Option #5: Remodel the Existing Restrooms on Floors 2 Through 10. Provide and Install NEW Efficient Plumbing and Electrical Fixtures, Including Upgrades on Finishes and ADA Compliance. F. Option #6: Remodel the Existing Restrooms on the First Floor. Provide and Install NEW Efficient Plumbing and Electrical Fixtures, Including Upgrades on Finishes and ADA Compliance. Location of the Restrooms MAY Change. G. Option #7: Remodel the Existing Kitchen. Provide and Install NEW Efficient Food Service Equipment, Hvac Upgrades, Plumbing and Electrical Fixtures, Including NEW Finishes. H. Option #8: Remove the Existing Two-Cell Cooling Tower. Provide and Install a NEW Four-Cell Cooling TOW

Contract Overview

Contract Amount: $28,259,589 ($28.3M)

Contractor: Neumann Brothers, Inc.

Awarding Agency: General Services Administration

Start Date: 2010-03-15

End Date: 2013-12-31

Contract Duration: 1,387 days

Daily Burn Rate: $20.4K/day

Official Description: RECOVERY: BUILDING #IA0112ZZ, NEAL SMITH FEDERAL BUILDING ARRA PROJECT (PROJECT #IIA00013), 210 WALNUT STREET, DES MOINES, IA. CONTRACT AWARD - WORK TO BE DELIVERED UNDER THIS TASK ORDER INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING: CHANGE OUT EXISTING ELECTRICAL AND MECHANICAL SYSTEMS TO UPGRADE PERFORMANCE OF ELECTRICAL AND HVAC SYSTEMS. AS OPTIONS, THE FOLLOWING ITEMS WILL BE INCLUDED IN THE SCOPE OF WORK: A. OPTION NO. 1 - CONSTRUCTION PHASE SERVICES: OPTION #1: A) ARRA REQUIRED PROJECTS-PROVIDE AND INSTALL ADVANCED METERING ON GAS AND WATER BUILDING SERVICE ENTRANCES; AND UPGRADES TO THE EXISTING ENERGY MANAGEMENT CONTROL SYSTEM (EMCS); B) ENERGY CONSERVATION MEASURES-PROVIDE AND INSTALL ENERGY SAVING LAMPS; OFFICE LIGHTING AND SWITCHING REVISIONS; DAYLIGHTING ENHANCEMENTS; PUBLIC AREA TIME OF DAY CONTROLS; COOLING TOWER SEWER ABATEMENT; BOILER AUTOMATIC BLOWDOWN; TIME OF DAY CONTROLS FOR EXISTING AIR HANDLING UNITS AND EXHAUST FANS; RESET DUAL DUCT MIXING BOX STATIC PRESSURE SENSORS; CHILLER CONTROL OPTIMIZATION; REPLACE EXISTING AIR HANDLING UNITS (ONE FOR ONE). B. OPTION #2: REMOVE BUILDING'S EXISTING PERIMETER INDUCTION UNITS. PROVIDE AND INSTALL A NEW PERIMETER RADIANT HEAT SYSTEM, INCLUDING A NEW VENTILATION AIR SYSTEM. C. OPTION #3: REMOVE BUILDING'S EXISTING ELECTRICAL POWER TRANSFORMERS. PROVIDE AND INSTALL NEW HIGHER EFFICIENCY TRANSFORMERS. D. OPTION #4: PROVIDE AND INSTALL NEW MOTORIZED AND CONTROLLED WINDOW BLIND SYSTEM AND NEW HIGHLY REFLECTIVE CEILING SYSTEM. E. OPTION #5: REMODEL THE EXISTING RESTROOMS ON FLOORS 2 THROUGH 10. PROVIDE AND INSTALL NEW EFFICIENT PLUMBING AND ELECTRICAL FIXTURES, INCLUDING UPGRADES ON FINISHES AND ADA COMPLIANCE. F. OPTION #6: REMODEL THE EXISTING RESTROOMS ON THE FIRST FLOOR. PROVIDE AND INSTALL NEW EFFICIENT PLUMBING AND ELECTRICAL FIXTURES, INCLUDING UPGRADES ON FINISHES AND ADA COMPLIANCE. LOCATION OF THE RESTROOMS MAY CHANGE. G. OPTION #7: REMODEL THE EXISTING KITCHEN. PROVIDE AND INSTALL NEW EFFICIENT FOOD SERVICE EQUIPMENT, HVAC UPGRADES, PLUMBING AND ELECTRICAL FIXTURES, INCLUDING NEW FINISHES. H. OPTION #8: REMOVE THE EXISTING TWO-CELL COOLING TOWER. PROVIDE AND INSTALL A NEW FOUR-CELL COOLING TOW.

Place of Performance

Location: Iowa, 50314

State: Iowa Government Spending

Related Pages